  1. Prepare Pipe Ends
  • Close the carriage with the minimal force necessary to FACE the pipe ends.
  • Continue facing until the jaws come into contact with both mechanical stops and have produced a minimum of one complete ribbon.
  • CLEAN fusion area after facing.
  • At FACING force, check ALIGNMENT of the pipe ends and check for GAPS.
  • Inspect, Clean & Install Pipe